Nabertherm LT 3/11 – LT 60/11 Muffle Furnace with Lift Door, 1100 °C
Laboratory muffle furnace for 1100 °C with a lift door, so the hot side of the door faces away from the operator. Seven chamber sizes from 3 to 60 litres, heated from two sides by ceramic heating plates (from three sides from 24 litres up). Available with controller B510 or C550.
- Key features Tmax 1100 °C
- Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
We reply to quote requests within one working day.
- Supplied through our manufacturer partnerships
- Installation, training and calibration on request
Overview
What this Nabertherm unit gives you, taken from the manufacturer data we hold on file.
- Key features Tmax 1100 °C
- Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
- Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
- Thermocouple type N
- Ceramic heating plates with integral heating element which is safeguarded and easy to replace
- Lift door with the hot surface facing away from the operator
- Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
- Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP)
- Adjustable air inlet integrated in door
- Exhaust air outlet in rear wall of furnace
- Controller B510 (5 programs with 4 segments each) or C550 (10 programs with 20 segments each)
- Technical data Model Tmax in °C¹ Inner dimensions in mm (w x d x h) Volume in l Outer dimensions² in mm (W x D x H³) Temperature uniformity of +/− 5K in the empty workspace⁵ (w x d x h) Connected load⁶ in kW Electrical connection Weight in kg Heating time in min⁴ LT 3/11 1100 160 x 140 x 100 3 385 x 330 x 405+155 110 x 50 x 50 1.3 1-phase 21 41 LT 5/11 1100 205 x 170 x 130 5 385 x 390 x 460+205 170 x 80 x 80 2.6 1-phase 27 47 LT 9/11 1100 235 x 240 x 170 9 415 x 455 x 515+240 180 x 150 x 120 3.3 1-phase 35 63 LT 15/11 1100 230 x 340 x 170 15 415 x 555 x 515+240 180 x 250 x 120 3.5 1-phase 43 74 LT 24/11 1100 280 x 340 x 250 24 490 x 555 x 580+320 230 x 250 x 200 4.9 3-phase 52 69 LT 40/11 1100 320 x 490 x 250 40 530 x 705 x 580+320 270 x 400 x 200 6.5 3-phase 70 80 LT 60/11 1100 380 x 490 x 330 60 610 x 705 x 660+385 290 x 360 x 240 9.8 3-phase 83 150 ¹ Recommended working temperature for processes with longer dwell times is 1000 °C (L../11) rsp. 1100 °C (L../12). ² External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. ³ Including opened lift door (LT models). ⁴ Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE rsp. 400 V 3/N/PE). ⁵ Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C. ⁶ The connected load refers to the standard furnace and may increase for a furnace with additional equipment. For furnaces with connection options for multi-range voltages, the connected load applies to the highest permissible connected voltage.
- Models and article numbers Model Article no. with controller B510 Article no. with controller C550 LT 3/11 L-035H1AL L-035H1AO LT 5/11 L-055H1AL L-055H1AO LT 9/11 L-095H1AL L-095H1AO LT 15/11 L-155H1AL L-155H1AO LT 24/11 L-245H1DL L-245H1DO LT 40/11 L-405H1DL L-405H1DO LT 60/11 L-606H1DL L-606H1DO Factory options that are ordered together with the furnace: protective gas connection (code G), over-temperature limiter (code T), thermocouple port Ø 11 mm in the rear wall (code Z), thermocouple port Ø 11 mm in the door (code Y).
- Additional equipment Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
- Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
- Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
- Manual or automatic gas supply system
- Port for thermocouple in the rear wall or in the furnace door
- Process control and documentation via VCD software package for monitoring, documentation and control
- Charging rack with closed or perforated trays for loading the furnace in two levels (max. 800 °C)
- Price on request. Tell us your application and we send an offer.
Delivery and support
Lead time depends on the manufacturer and the configuration, so we confirm it with your quote. Delivery, installation, operator training and calibration can all be included, and we will price them separately so you can see what each part costs.
Tell us the country you need it delivered to and we will quote transport and any documentation your institution requires.
Ask about this item
Your quote list
This item is ready to send. Add anything else you need from the related items below and it goes out as one request.
Not sure which model fits your work?
Send us your samples, throughput and the standard you work to. We will come back with the model that fits and a written quote.