{"product_id":"nabertherm-lh-12-chamber-furnace-brick-insulation-1200c","title":"Nabertherm LH 15\/12 – LH 216\/12 Chamber Furnace with Brick Insulation, 1200 °C","description":"\u003cp\u003eChamber furnace for the laboratory with multi-layer insulation of light refractory bricks and heating from five sides, maximum temperature 1200 °C. Five sizes from 15 to 216 litres; the base is included and the controller can be taken off the door for operation. Available with controller B500 or C540.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTmax 1200 °C\u003c\/li\u003e\n\u003cli\u003eDual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature\u003c\/li\u003e\n\u003cli\u003eHigh furnace chamber with five-sided heating for very good temperature uniformity\u003c\/li\u003e\n\u003cli\u003eHeating elements on support tubes ensure free heat radiation and a long service life\u003c\/li\u003e\n\u003cli\u003eProtection of bottom heating and flat stacking surface provided by embedded SiC plate in the floor\u003c\/li\u003e\n\u003cli\u003eLH models: multi-layered insulation of light refractory bricks and special backup insulation\u003c\/li\u003e\n\u003cli\u003eExclusive use of insulation materials without categorization according to EC Regulation No. 1272\/2008 (CLP)\u003c\/li\u003e\n\u003cli\u003eDoor with brick-on-brick seal, hand fitted\u003c\/li\u003e\n\u003cli\u003eGenerously dimensioned heating provides for short heating times\u003c\/li\u003e\n\u003cli\u003eSelf-supporting arch for high stability and greatest possible protection against dust\u003c\/li\u003e\n\u003cli\u003eController B500 (5 programs with 4 segments each) or C540 (10 programs with 20 segments each)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTmax in °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInner dimensions in mm (w x d x h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume in l\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter dimensions¹ in mm (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConnected load³ in kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight in kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 15\/12\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e250 x 250 x 250\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e680 x 860 x 1230\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e3-phase²\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 30\/12\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e320 x 320 x 320\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e710 x 930 x 1290\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e3-phase²\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 60\/12\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e400 x 400 x 400\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e790 x 1180 x 1370\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 120\/12\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e500 x 500 x 500\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e890 x 1180 x 1470\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 216\/12\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e600 x 600 x 600\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003ctd\u003e990 x 1280 x 1590\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e¹ External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. ² Heating only between two phases. ³ The connected load refers to the standard furnace and may increase for a furnace with additional equipment. For furnaces with connection options for multi-range voltages, the connected load applies to the highest permissible connected voltage.\u003c\/p\u003e\u003ch2\u003eModels and article numbers\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle no. with controller B500\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle no. with controller C540\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 15\/12\u003c\/td\u003e\n\u003ctd\u003eLH0222NKNE\u003c\/td\u003e\n\u003ctd\u003eLH0222NMNE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 30\/12\u003c\/td\u003e\n\u003ctd\u003eLH0322NKNE\u003c\/td\u003e\n\u003ctd\u003eLH0322NMNE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 60\/12\u003c\/td\u003e\n\u003ctd\u003eLH0622NKNE\u003c\/td\u003e\n\u003ctd\u003eLH0622NMNE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 120\/12\u003c\/td\u003e\n\u003ctd\u003eLH1222NKNE\u003c\/td\u003e\n\u003ctd\u003eLH1222NMNE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLH 216\/12\u003c\/td\u003e\n\u003ctd\u003eLH2122NKNE\u003c\/td\u003e\n\u003ctd\u003eLH2122NMNE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eAdditional equipment\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eParallel swinging door (user protected from heat radiation)\u003c\/li\u003e\n\u003cli\u003eLift door with electro-mechanic linear drive for opening when hot\u003c\/li\u003e\n\u003cli\u003eCooling system to cool the furnace with a defined temperature gradient or with a preset fresh air volume\u003c\/li\u003e\n\u003cli\u003eProtective gas connection to purge with non-flammable process gases\u003c\/li\u003e\n\u003cli\u003eManual or automatic gas supply system\u003c\/li\u003e\n\u003cli\u003eStainless steel hood for discharge of exhaust gases\/exhaust air as an interface to the customer's extraction system\u003c\/li\u003e\n\u003cli\u003eScale to measure weight reduction during annealing\u003c\/li\u003e\n\u003cli\u003eOver-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003ePrice on request. Tell us your application and we send an offer.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"LH 15\/12\/B500","offer_id":51067616395334,"sku":"LH0222NKNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 15\/12\/C540","offer_id":51067616428102,"sku":"LH0222NMNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 30\/12\/B500","offer_id":51067616460870,"sku":"LH0322NKNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 30\/12\/C540","offer_id":51067616493638,"sku":"LH0322NMNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 60\/12\/B500","offer_id":51067616526406,"sku":"LH0622NKNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 60\/12\/C540","offer_id":51067616559174,"sku":"LH0622NMNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 120\/12\/B500","offer_id":51067616591942,"sku":"LH1222NKNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 120\/12\/C540","offer_id":51067616624710,"sku":"LH1222NMNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 216\/12\/B500","offer_id":51067616657478,"sku":"LH2122NKNE","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"LH 216\/12\/C540","offer_id":51067616690246,"sku":"LH2122NMNE","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/nabertherm-lh30-14-0_64b59971-b34c-493b-bb97-a5359a07b570.jpg?v=1794954837","url":"https:\/\/bielengineering.com\/products\/nabertherm-lh-12-chamber-furnace-brick-insulation-1200c","provider":"BIEL engineering","version":"1.0","type":"link"}