{"product_id":"nabertherm-ht-18-high-temperature-furnace-fibre-insulation-1800c","title":"Nabertherm HT 08\/18 – HT 450\/18 High-Temperature Furnace with MoSi₂ Heating and Fibre Insulation, 1800 °C","description":"\u003cp\u003eFree-standing high-temperature furnace with molybdenum disilicide heating elements on both sides and fibre insulation, maximum temperature 1800 °C. Nine sizes from 8 to 450 litres. Nabertherm states a temperature uniformity of up to +\/− 6 °C at 1450 °C according to DIN 17052-1. Controller P570.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTmax 1800 °C\u003c\/li\u003e\n\u003cli\u003eRecommended maximum working temperature approx. 50 °C below Tmax of the furnace. Higher working temperatures will increase wear and tear\u003c\/li\u003e\n\u003cli\u003eDual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability\u003c\/li\u003e\n\u003cli\u003eHeating from both sides via molybdenum disilicide heating elements\u003c\/li\u003e\n\u003cli\u003eHigh-quality fiber insulation backed by special insulation\u003c\/li\u003e\n\u003cli\u003eLong-life roof insulation with special suspension\u003c\/li\u003e\n\u003cli\u003eTemperature uniformity at 1450 °C up to +\/− 6 °C according to DIN 17052-1\u003c\/li\u003e\n\u003cli\u003eExclusive use of insulation materials without categorization according to EC Regulation No 1272\/2008 (CLP)\u003c\/li\u003e\n\u003cli\u003eChain-guided parallel swivel door for defined opening and closing of the door\u003c\/li\u003e\n\u003cli\u003eTwo-door design (front\/back) for high-temperature furnaces \u0026gt; HT 276\/.\u003c\/li\u003e\n\u003cli\u003eController P570 (50 programs with 40 segments each)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical data\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTmax °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInner dimensions in mm (w x d x h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume in l\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter dimensions¹ in mm (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConnected load³ kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight in kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 08\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e150 x 300 x 150\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e740 x 640 x 1755\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003ctd\u003e3-phase²\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 16\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e200 x 300 x 260\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e820 x 690 x 1860\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e3-phase²\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 29\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e275 x 300 x 350\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e985 x 740 x 1990\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003ctd\u003e3-phase²\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 40\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e300 x 350 x 350\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e1010 x 800 x 1990\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 64\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e400 x 400 x 400\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e1140 x 890 x 2040\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 128\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e400 x 800 x 400\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003ctd\u003e1140 x 1280 x 2040\u003c\/td\u003e\n\u003ctd\u003e26.5\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 160\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e500 x 550 x 550\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e1250 x 1040 x 2260\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 276\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e500 x 1000 x 550\u003c\/td\u003e\n\u003ctd\u003e276\u003c\/td\u003e\n\u003ctd\u003e1340 x 1600 x 2290\u003c\/td\u003e\n\u003ctd\u003e43.5\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e1270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 450\/18\u003c\/td\u003e\n\u003ctd\u003e1800\u003c\/td\u003e\n\u003ctd\u003e500 x 1150 x 780\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003e1380 x 1820 x 2570\u003c\/td\u003e\n\u003ctd\u003e65.0\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003e1570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e¹ External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. ² Heating only between two phases. ³ The connected load refers to the standard furnace and may increase for a furnace with additional equipment. For furnaces with connection options for multi-range voltages, the connected load applies to the highest permissible connected voltage.\u003c\/p\u003e\u003ch2\u003eModels and article numbers\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle no. with controller P570\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 08\/18\u003c\/td\u003e\n\u003ctd\u003eHT0248VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 16\/18\u003c\/td\u003e\n\u003ctd\u003eHT0358VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 29\/18\u003c\/td\u003e\n\u003ctd\u003eHT0558VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 40\/18\u003c\/td\u003e\n\u003ctd\u003eHT0458VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 64\/18\u003c\/td\u003e\n\u003ctd\u003eHT0658VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 128\/18\u003c\/td\u003e\n\u003ctd\u003eHT1258VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 160\/18\u003c\/td\u003e\n\u003ctd\u003eHT1658VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 276\/18\u003c\/td\u003e\n\u003ctd\u003eHT2758VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHT 450\/18\u003c\/td\u003e\n\u003ctd\u003eHT4558VNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eAdditional equipment\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCooling system to cool the furnace with a defined temperature gradient or with a preset fresh air volume\u003c\/li\u003e\n\u003cli\u003eSafety package for debinding in air\u003c\/li\u003e\n\u003cli\u003eThermocouple inlet with screw cap\u003c\/li\u003e\n\u003cli\u003eThermocouple for the heating control with calibration certificate\u003c\/li\u003e\n\u003cli\u003eProtective gas connection to purge with non-flammable process gases (not completely gas-tight)\u003c\/li\u003e\n\u003cli\u003eAutomatic gas supply system with solenoid valve and rotameter, controlled by the extra function of the controller\u003c\/li\u003e\n\u003cli\u003eRefractory brick floor insulation for a higher floor load (Tmax 1700 °C)\u003c\/li\u003e\n\u003cli\u003eLift door\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003ePrice on request. Tell us your application and we send an offer.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"HT 08\/18\/P570","offer_id":51067617542214,"sku":"HT0248VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 16\/18\/P570","offer_id":51067617574982,"sku":"HT0358VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 29\/18\/P570","offer_id":51067617607750,"sku":"HT0558VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 40\/18\/P570","offer_id":51067617640518,"sku":"HT0458VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 64\/18\/P570","offer_id":51067617673286,"sku":"HT0658VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 128\/18\/P570","offer_id":51067617706054,"sku":"HT1258VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 160\/18\/P570","offer_id":51067617738822,"sku":"HT1658VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 276\/18\/P570","offer_id":51067617771590,"sku":"HT2758VNA","price":0.0,"currency_code":"EUR","in_stock":true},{"title":"HT 450\/18\/P570","offer_id":51067617804358,"sku":"HT4558VNA","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/nabertherm-ht29-17_4691d6fe-4c69-4af8-947c-8e6ef4eb31f0.jpg?v=1794954863","url":"https:\/\/bielengineering.com\/products\/nabertherm-ht-18-high-temperature-furnace-fibre-insulation-1800c","provider":"BIEL engineering","version":"1.0","type":"link"}