{"product_id":"ika-vc-10-pro-vacuum-controller","title":"IKA VC 10 pro Vacuum controller","description":"\u003cp\u003eValve-controlled, universal vacuum controller for controlled evacuation of air (gas) from laboratory equipment, as well as for classical separation, filtration or drying tasks in the laboratory. The controller is ready-to-use in numerous applications and can be easily installed.\u003c\/p\u003e\n\u003cp\u003eVC 10 pro can be used with all standard vacuum sources. The use of multiple controllers with one vacuum source is possible.\u003c\/p\u003e\n\u003cp\u003eFeatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/off regulation of multiple vacuum sources\u003c\/li\u003e\n\u003cli\u003eAutomatic boiling point detection\u003c\/li\u003e\n\u003cli\u003eIntegrated solvent library: Helps to set the correct parameters for example in evaporation processes with rotary evaporators\u003c\/li\u003e\n\u003cli\u003eGraph function\u003c\/li\u003e\n\u003cli\u003eConnection for external temperature sensor: temperature value is shown on display\u003c\/li\u003e\n\u003cli\u003eValve cleaning function for long service life\u003c\/li\u003e\n\u003cli\u003eIntegrated ventilation valve for simple pressure equalization and aeration with inert gas after process completion\u003c\/li\u003e\n\u003cli\u003eVENT short key button allows pressure equalization during a running process\u003c\/li\u003e\n\u003cli\u003eProgram function: up to ten user-defined programs can be saved, with up to ten pressure\/time sequences\u003c\/li\u003e\n\u003cli\u003eUSB \/ RS232 interfaces for connection with the laboratory software labworldsoft®\u003c\/li\u003e\n\u003cli\u003eElectronic control system for improved process efficiency and higher solvent recovery rate\u003c\/li\u003e\n\u003cli\u003eHigh energy efficiency thanks to device-to-device communication (vacuum controller to recirculating chiller)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor additional safety for users and environment, the use of the VSE 1 vacuum safety emission condenser is recommended, which prevents solvents from being released into the room air. The VSE 1 is available as an accessory.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter suction side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter pressure side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter venting side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e1 - 1050 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTwo-point control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog speed vacuum control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure unit \/ scale\u003c\/th\u003e\n\u003ctd\u003embar, hPa, mmHg, Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor type\u003c\/th\u003e\n\u003ctd\u003eceramic Al2O3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure max. for pressure sensor\u003c\/th\u003e\n\u003ctd\u003e1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement range (absolute)\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement uncertainty\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedium temperature (gas)\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate trap\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection for ext. temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature unit\u003c\/th\u003e\n\u003ctd\u003e°C \/ °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measuring range\u003c\/th\u003e\n\u003ctd\u003e-10 - 200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measurement resolution\u003c\/th\u003e\n\u003ctd\u003e1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy of temperature measurement\u003c\/th\u003e\n\u003ctd\u003e±1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTime setting min.\u003c\/th\u003e\n\u003ctd\u003e1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTime setting max.\u003c\/th\u003e\n\u003ctd\u003e6000 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum speed control interface\u003c\/th\u003e\n\u003ctd\u003eVACSTAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003eAl2O3, PTFE, FPM, PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClean room qualified\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExplosion proofed\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFastening\u003c\/th\u003e\n\u003ctd\u003estand \/ clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFastening diameter\u003c\/th\u003e\n\u003ctd\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode automatic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode manual\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode pump %\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode program\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGraph function\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum leakage test\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e95 x 150 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog output\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input standby\u003c\/th\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDC Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.300 Check valve\u003c\/td\u003e\n\u003ctd\u003e0020011105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.400 Stand\u003c\/td\u003e\n\u003ctd\u003e0035001735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 2.4 Pump control\u003c\/td\u003e\n\u003ctd\u003e0002439100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT 1000.60 Temperature sensor, stainless steel\u003c\/td\u003e\n\u003ctd\u003e0003516800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVH.SI.8 Vacuum hose\u003c\/td\u003e\n\u003ctd\u003e0020013886\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSE 1\u003c\/td\u003e\n\u003ctd\u003e0035001873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC 1.3 Cable\u003c\/td\u003e\n\u003ctd\u003e0025005322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR-2.ST the High-Performer\u003c\/td\u003e\n\u003ctd\u003e0020013291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020112031.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991788949574,"sku":"0020112031","price":1627.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vc-10-pro-vacuum-controller.jpg?v=1794350762","url":"https:\/\/bielengineering.com\/products\/ika-vc-10-pro-vacuum-controller","provider":"BIEL engineering","version":"1.0","type":"link"}