{"product_id":"ika-vacstar-control-membrane-vacuum-pump","title":"IKA VACSTAR control Membrane vacuum pump","description":"\u003cp\u003eSeparation, filtration, removal: The VACSTAR dry 4-chamber membrane vacuum pump is powerful, resistant to chemicals and low-maintenance. VACSTAR control is the ideal system with its integrated vacuum controller and removable display. The controller offers a suitable mode for the desired process: from automatic to manual operation, right through to pumping or an evacuation and cleaning function.\u003c\/p\u003e\n\u003cp\u003eHigh-performance suction\u003cbr\u003eVACSTAR has an excellent suction performance, with its 22 l\/min at a minimum of 2 mbar.\u003c\/p\u003e\n\u003cp\u003eIntegrated vacuum controller with removable controller (WiCo)\u003cbr\u003eDepending on the application, you can easily select your operating mode either by using the intuitive operator menu or by remote control.\u003c\/p\u003e\n\u003cp\u003eFor additional safety for users and environment, we recommend using the VSE 1 vacuum safety emission condenser, which prevents solvents from being released into the room air. The VSE 1 is available as accessory.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1.32 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e22 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure without gas ballast\u003c\/th\u003e\n\u003ctd\u003e2 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction levels\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter suction side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter pressure side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas ballast valve\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e2 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog speed vacuum control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed adjustment\u003c\/th\u003e\n\u003ctd\u003eTurning knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1200 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure unit \/ scale\u003c\/th\u003e\n\u003ctd\u003embar, hPa, mmHg, Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor type\u003c\/th\u003e\n\u003ctd\u003eceramic Al2O3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure max. for pressure sensor\u003c\/th\u003e\n\u003ctd\u003e1.2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement range (absolute)\u003c\/th\u003e\n\u003ctd\u003e1 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement uncertainty\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum valve\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate trap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003eAl2O3, PTFE, FPM, PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ealu-cast coating \/ thermoplastic polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClean room qualified\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExplosion proofed\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode automatic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode manual\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode pump %\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode program\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e270 x 435 x 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80% (up to 31°C), decreasing linearly to max. 50 (@40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e140 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input standby\u003c\/th\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSW 1\u003c\/td\u003e\n\u003ctd\u003e0020015406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSE 1\u003c\/td\u003e\n\u003ctd\u003e0035001873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVH.SI.8 Vacuum hose\u003c\/td\u003e\n\u003ctd\u003e0020013886\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY hose connector 8 mm\u003c\/td\u003e\n\u003ctd\u003e0020010963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Starter\u003c\/td\u003e\n\u003ctd\u003e0020019397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Advanced\u003c\/td\u003e\n\u003ctd\u003e0020105873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Pro\u003c\/td\u003e\n\u003ctd\u003e0020017366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR-2.ST the High-Performer\u003c\/td\u003e\n\u003ctd\u003e0020013291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020109375.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991788621894,"sku":"0020109375","price":4863.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-control-membrane-vacuum-pump.jpg?v=1794350753","url":"https:\/\/bielengineering.com\/products\/ika-vacstar-control-membrane-vacuum-pump","provider":"BIEL engineering","version":"1.0","type":"link"}