{"product_id":"ika-rc-5-control-recirculating-chiller","title":"IKA RC 5 control Recirculating chiller","description":"\u003cp\u003ePowerful recirculating chiller, designed for external cooling applications up to -30°C.\u003cbr\u003eThe energy-efficient chiller is operated with an eco-friendly refrigerant and reaches a high power density. This results in a comparatively small working space in the lab. The speed-controlled PEEK pump allows an indirect, continuous adjustment of the maximum pressure and flow rate. Due to the PT100 temperature sensor, which is part of the delivery and its excellent temperature stability of about ± 0,1 K, the RC 5 can handle even sophisticated applications.\u003cbr\u003eLaboratory staff operates the RC 5 control safely and conveniently from everywhere in the lab by using the Wireless Controller (WiCo). Processes can be automated and simplified through 10 freely programmable temperature ramps with 10 steps each.\u003cbr\u003eIts isolated, high-quality 7l bath has an integrated hopper and drain valve, ensuring safe and clean handling of the thermofluid. A hose can be connected to empty the bath in order to avoid direct contact with the thermofluid.\u003cbr\u003eThe easy-to-open front flap allows an easy cleaning of the cooling unit’s air filter.\u003c\/p\u003e\n\u003cp\u003eKey Features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpeed-controlled refrigeration system with 1400 W cooling capacity (@20°C)\u003c\/li\u003e\n\u003cli\u003eNatural thermofluid R290\u003c\/li\u003e\n\u003cli\u003eDesigned for cooling applications up to -30°C - RT\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range up to 80°C\u003c\/li\u003e\n\u003cli\u003eExcellent temperature stability of about ± 0,1K (@-10°C)\u003c\/li\u003e\n\u003cli\u003eSpeed-controlled pump made of PEEK: (0,6 bar; 31l\/min)\u003c\/li\u003e\n\u003cli\u003eDigital level indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional benefits of the control device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating mode D (confirmation mode)\u003c\/li\u003e\n\u003cli\u003eSignal if set point is reached\u003c\/li\u003e\n\u003cli\u003eTimer\/Counter\u003c\/li\u003e\n\u003cli\u003eDegassing function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInterfaces:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection socket for external PT 100 temperature sensor (Accessory: PT100.30; Lemo connector)\u003c\/li\u003e\n\u003cli\u003eConnection of magnetic valves possible (Mulit IO)\u003c\/li\u003e\n\u003cli\u003eAlarm contact (Multi IO)\u003c\/li\u003e\n\u003cli\u003eConnector for standby contact input (Multi IO)\u003c\/li\u003e\n\u003cli\u003eRS 232 and USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAppliance type\u003c\/th\u003e\n\u003ctd\u003eRecirculating chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent\u003c\/th\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent quantity\u003c\/th\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent pressure max.\u003c\/th\u003e\n\u003ctd\u003e21 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@20°C)\u003c\/th\u003e\n\u003ctd\u003e1400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@10°C)\u003c\/th\u003e\n\u003ctd\u003e1200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@0°C)\u003c\/th\u003e\n\u003ctd\u003e950 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@-10°C)\u003c\/th\u003e\n\u003ctd\u003e650 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@-20°C)\u003c\/th\u003e\n\u003ctd\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@-30°C)\u003c\/th\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature\u003c\/th\u003e\n\u003ctd\u003e-30 - room temp. °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature min.\u003c\/th\u003e\n\u003ctd\u003e-30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature max. (with external heating)\u003c\/th\u003e\n\u003ctd\u003e80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature display\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd\u003ePID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature display\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature stability DIN 12876\u003c\/th\u003e\n\u003ctd\u003e±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection for ext. temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay for operation with ext. sensor\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function optical\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function acoustic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function excess temperature\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function insufficient temperature\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSub-level protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFilling volume\u003c\/th\u003e\n\u003ctd\u003e5.0 - 7.0 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump type\u003c\/th\u003e\n\u003ctd\u003ePressure- \/ suction pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump capacity adjustable\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump pressure max. (0 liters discharge flow)\u003c\/th\u003e\n\u003ctd\u003e0.61 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure pump (suction side) (0 liter flow)\u003c\/th\u003e\n\u003ctd\u003e0.45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow rate max. (0 bar back pressure)\u003c\/th\u003e\n\u003ctd\u003e31 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump connection\u003c\/th\u003e\n\u003ctd\u003eM16x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCalibration option\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTechnical data complies with the standard\u003c\/th\u003e\n\u003ctd\u003eDIN 12876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ON time\u003c\/th\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMulti-Interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm output (potential-free contact) max.\u003c\/th\u003e\n\u003ctd\u003e30 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm output (potential-free contact) max.\u003c\/th\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolenoid valve output\u003c\/th\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolenoid valve output max.\u003c\/th\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandby input\u003c\/th\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise level\u003c\/th\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e310 x 546 x 490 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e37.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 32 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e1100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUF.Si.N30.150.10LV\u003c\/td\u003e\n\u003ctd\u003e0020003518\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.8.R Tube\u003c\/td\u003e\n\u003ctd\u003e0020004612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0020004613\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.20 Hose kit (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0002606700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.21 Hose kit insulated (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0020000988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO.8\u003c\/td\u003e\n\u003ctd\u003e0004569400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO.12\u003c\/td\u003e\n\u003ctd\u003e0004569500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBall valve M16x1\u003c\/td\u003e\n\u003ctd\u003e0020004620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emechanic fluid level controller\u003c\/td\u003e\n\u003ctd\u003e0020004618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB 8 eco\u003c\/td\u003e\n\u003ctd\u003e0004248100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB 18 eco\u003c\/td\u003e\n\u003ctd\u003e0004248200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB HF 24 eco\u003c\/td\u003e\n\u003ctd\u003e0020006884\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB 9 pro\u003c\/td\u003e\n\u003ctd\u003e0004248500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB 12 pro\u003c\/td\u003e\n\u003ctd\u003e0004577500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB 20 pro\u003c\/td\u003e\n\u003ctd\u003e0004248600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB R RO 15 eco\u003c\/td\u003e\n\u003ctd\u003e0020006341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB R 9 eco\u003c\/td\u003e\n\u003ctd\u003e0020004382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB R 20 eco\u003c\/td\u003e\n\u003ctd\u003e0020004383\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIB R 52 eco\u003c\/td\u003e\n\u003ctd\u003e0020007044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eelbow tube 90°\u003c\/td\u003e\n\u003ctd\u003e0025001212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 6 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 8 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 10 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 12 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004889\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004569\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/2 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 3\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003elock nut (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004583\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estopper (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMV 1 Magnetic valve\u003c\/td\u003e\n\u003ctd\u003e0020003763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO V 1 Closed pressure valve\u003c\/td\u003e\n\u003ctd\u003e0020000249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT 100.30 Temperature sensor\u003c\/td\u003e\n\u003ctd\u003e0004284700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT 100 extension (LEMO)\u003c\/td\u003e\n\u003ctd\u003e0020004629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Pro\u003c\/td\u003e\n\u003ctd\u003e0020017366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Starter\u003c\/td\u003e\n\u003ctd\u003e0020019397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.30 Tempering hose 800 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020108012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.31 Tempering hose 1200 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020110278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.32 Tempering hose 1600 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020113271\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 6000.1 Water protect, 100 ml\u003c\/td\u003e\n\u003ctd\u003e0020014031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY hose connector 8 mm\u003c\/td\u003e\n\u003ctd\u003e0020010963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0004183000.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991788294214,"sku":"0004183000","price":7453.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-rc-5-control-recirculating-chiller.jpg?v=1794350742","url":"https:\/\/bielengineering.com\/products\/ika-rc-5-control-recirculating-chiller","provider":"BIEL engineering","version":"1.0","type":"link"}