{"product_id":"ika-rc-2-green-basic-recirculating-chiller","title":"IKA RC 2 GREEN basic Recirculating chiller","description":"\u003cp\u003ePowerful, compact and energy-efficient circulating chiller for cooling applications up to -30 °C. The on-demand and speed-controlled compressor, operated with natural refrigerant, achieves a cooling capacity of 800 W at a minimum energy consumption.\u003c\/p\u003e\n\u003cp\u003eThe speed-controlled PEEK pump allows an indirect continuous adjustment of maximum pressure and flow rate. The integrated filling funnel and drain valve enable safe and clean handling of the thermofluid. With regular cleaning, the easily accessible stainless steel woven mesh air filter guarantees consistent performance.\u003cbr\u003eThe high-quality insulated 4 l bath reservoir allows the use of up to 2.5 l of thermofluid in the external cooling circle without refilling.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ehighly efficient speed-controlled cooling unit with a cooling capacity of 800 W (@20 °C)\u003c\/li\u003e\n\u003cli\u003enatural refrigerant R290\u003c\/li\u003e\n\u003cli\u003espeed-controlled PEEK pump: (0.5 bar; 21 l\/min)\u003c\/li\u003e\n\u003cli\u003edigital level indicator\u003c\/li\u003e\n\u003cli\u003ebig LED-Display\u003c\/li\u003e\n\u003cli\u003eoptical and acoustic warning functions\u003c\/li\u003e\n\u003cli\u003eeasy-to-clean stainless steel mesh filter\u003c\/li\u003e\n\u003cli\u003ehigh quality insulated 4 l bath reservoir (minimum 1.5 l)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInterfaces:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRS 232 and USB for controlling and monitoring the devices via labworldsoft® and to update the software online\u003c\/li\u003e\n\u003cli\u003eCalibrateable internal temperature sensor (3 point)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAppliance type\u003c\/th\u003e\n\u003ctd\u003eRecirculating chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent\u003c\/th\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent quantity\u003c\/th\u003e\n\u003ctd\u003e69 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent pressure max.\u003c\/th\u003e\n\u003ctd\u003e21 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@20°C)\u003c\/th\u003e\n\u003ctd\u003e800 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@10°C)\u003c\/th\u003e\n\u003ctd\u003e700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@0°C)\u003c\/th\u003e\n\u003ctd\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@-10°C)\u003c\/th\u003e\n\u003ctd\u003e400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@-20°C)\u003c\/th\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@-30°C)\u003c\/th\u003e\n\u003ctd\u003e90 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature\u003c\/th\u003e\n\u003ctd\u003e-30 - room temp. °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature min.\u003c\/th\u003e\n\u003ctd\u003e-30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature max. (with external heating)\u003c\/th\u003e\n\u003ctd\u003e70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature display\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature stability DIN 12876 (@-10°C)\u003c\/th\u003e\n\u003ctd\u003e±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature display\u003c\/th\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety temperature display\u003c\/th\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature stability DIN 12876\u003c\/th\u003e\n\u003ctd\u003e±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet temperature resolution\u003c\/th\u003e\n\u003ctd\u003e±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function optical\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function acoustic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function excess temperature\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function insufficient temperature\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSub-level protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOver-level protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFilling volume\u003c\/th\u003e\n\u003ctd\u003e1.4 - 4.0 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump type\u003c\/th\u003e\n\u003ctd\u003ePressure- \/ suction pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump capacity adjustable\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump pressure max. (0 liters discharge flow)\u003c\/th\u003e\n\u003ctd\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure pump (suction side) (0 liter flow)\u003c\/th\u003e\n\u003ctd\u003e0.25 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow rate max. (0 bar back pressure)\u003c\/th\u003e\n\u003ctd\u003e21 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump connection\u003c\/th\u003e\n\u003ctd\u003eM16x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCalibration option\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTechnical data complies with the standard\u003c\/th\u003e\n\u003ctd\u003eDIN 12876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise level\u003c\/th\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e220 x 475 x 525 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e25.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 32 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e350 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUF.Si.N30.150.10LV\u003c\/td\u003e\n\u003ctd\u003e0020003518\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF.EG48.N30.80.22\u003c\/td\u003e\n\u003ctd\u003e0020003522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF.EG100\u003c\/td\u003e\n\u003ctd\u003e0020004883\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBath cleaner\u003c\/td\u003e\n\u003ctd\u003e0020004610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estainless steel surface cleaner\u003c\/td\u003e\n\u003ctd\u003e0020004611\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.20 Hose kit (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0002606700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.21 Hose kit insulated (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0020000988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.8.R Tube\u003c\/td\u003e\n\u003ctd\u003e0020004612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0020004613\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO.8\u003c\/td\u003e\n\u003ctd\u003e0004569400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO.12\u003c\/td\u003e\n\u003ctd\u003e0004569500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBall valve M16x1\u003c\/td\u003e\n\u003ctd\u003e0020004620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emechanic fluid level controller\u003c\/td\u003e\n\u003ctd\u003e0020004618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eelbow tube 90°\u003c\/td\u003e\n\u003ctd\u003e0025001212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 6 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 8 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 12 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004889\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 10 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004569\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/2 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 3\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003elock nut (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004583\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estopper (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Pro\u003c\/td\u003e\n\u003ctd\u003e0020017366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Starter\u003c\/td\u003e\n\u003ctd\u003e0020019397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.30 Tempering hose 800 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020108012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.31 Tempering hose 1200 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020110278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.6\u003c\/td\u003e\n\u003ctd\u003e0020102324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.32 Tempering hose 1600 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020113271\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY hose connector 8 mm\u003c\/td\u003e\n\u003ctd\u003e0020010963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 6000.1 Water protect, 100 ml\u003c\/td\u003e\n\u003ctd\u003e0020014031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0025004186.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991787900998,"sku":"0025004186","price":4480.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-rc-2-green-basic-recirculating-chiller.jpg?v=1794350730","url":"https:\/\/bielengineering.com\/products\/ika-rc-2-green-basic-recirculating-chiller","provider":"BIEL engineering","version":"1.0","type":"link"}