{"product_id":"ika-hrc-2-lite-cooling-and-heating-circulator","title":"IKA HRC 2 lite Cooling and heating circulator","description":"\u003cp\u003eCompact refrigerated and heating circulator with powerful 400 W cooling and 1000 W heating capacity, designed for simple tempering tasks down from -10 to 100 °C.\u003c\/p\u003e\n\u003cp\u003eThe HRC 2 lite is the perfect peripheral device for tempering bioreactors and laboratory reactors, open bath solutions or serves as a tempering source for measuring devices. With its compact and space-saving design, the refrigerated and heating circulator even fits in confined laboratory space conditions.\u003c\/p\u003e\n\u003cp\u003eThe easily accessible and easy-to-clean mesh filter (stainless steel) ensures a consistently high cooling capacity over years. Thanks to the low filling volume of just one liter, the HRC 2 lite is able to reach the desired temperatures particularly fast. Its large working volume of 2.5 liters enables a high number of external applications without the need of refilling thermal fluids. The filling level in the reservoir can be read through the large, illuminated sight glass.\u003c\/p\u003e\n\u003cp\u003eWith the powerful pressure and suction pump it is possible to carry out demanding applications as well as external applications in open bath vessels in combination with a level controller. Thanks to the natural refrigerant R290, the HRC 2 lite is remarkably sustainable and well prepared for the future.\u003c\/p\u003e\n\u003cp\u003eThe devices of the lite series can be ideally used as peripheral devices. In order to ensure the most convenient handling of the application, they are equipped with an RS 232 and USB interface and can thus be controlled directly via the respective main device using device-to-device communication. Control and monitoring via labworldsoft® and other laboratory software is also possible.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAppliance type\u003c\/th\u003e\n\u003ctd\u003eRefrigerated and heating circulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClass designation acc. DIN 12876\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentification according to DIN 12876\u003c\/th\u003e\n\u003ctd\u003eFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent\u003c\/th\u003e\n\u003ctd\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent quantity\u003c\/th\u003e\n\u003ctd\u003e79 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling agent pressure max.\u003c\/th\u003e\n\u003ctd\u003e21 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat output\u003c\/th\u003e\n\u003ctd\u003e1000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@20°C)\u003c\/th\u003e\n\u003ctd\u003e400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@10°C)\u003c\/th\u003e\n\u003ctd\u003e350 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@0°C)\u003c\/th\u003e\n\u003ctd\u003e250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity (@-10°C)\u003c\/th\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature\u003c\/th\u003e\n\u003ctd\u003e-10 - 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature min.\u003c\/th\u003e\n\u003ctd\u003e-10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature display\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature stability DIN 12876 (@+70°C)\u003c\/th\u003e\n\u003ctd\u003e±0.05 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature stability DIN 12876 (@-10°C)\u003c\/th\u003e\n\u003ctd\u003e±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd\u003ePID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature display\u003c\/th\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet temperature resolution\u003c\/th\u003e\n\u003ctd\u003e±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function optical\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function acoustic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function excess temperature\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAdjustable safety circuit\u003c\/th\u003e\n\u003ctd\u003e0 - 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSub-level protection\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOver-level protection\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFilling volume\u003c\/th\u003e\n\u003ctd\u003e1 - 3.5 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump type\u003c\/th\u003e\n\u003ctd\u003ePressure- \/ suction pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump capacity adjustable\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump pressure max. (0 liters discharge flow)\u003c\/th\u003e\n\u003ctd\u003e0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure pump (suction side) (0 liter flow)\u003c\/th\u003e\n\u003ctd\u003e0.15 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow rate max. (0 bar back pressure)\u003c\/th\u003e\n\u003ctd\u003e18 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump connection\u003c\/th\u003e\n\u003ctd\u003eM16x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCalibration option\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTechnical data complies with the standard\u003c\/th\u003e\n\u003ctd\u003eDIN 12876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ON time\u003c\/th\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise level\u003c\/th\u003e\n\u003ctd\u003e51 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e225 x 385 x 430 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e24.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 32 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e1250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.20 Hose kit (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0002606700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.21 Hose kit insulated (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0020000988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.8.R Tube\u003c\/td\u003e\n\u003ctd\u003e0020004612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0020004613\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO.8\u003c\/td\u003e\n\u003ctd\u003e0004569400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY hose connector 8 mm\u003c\/td\u003e\n\u003ctd\u003e0020010963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBall valve M16x1\u003c\/td\u003e\n\u003ctd\u003e0020004620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emechanic fluid level controller\u003c\/td\u003e\n\u003ctd\u003e0020004618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eelbow tube 90°\u003c\/td\u003e\n\u003ctd\u003e0025001212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 6 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 8 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 12 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004889\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 10 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004569\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/2 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 3\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003elock nut (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004583\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estopper (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Pro\u003c\/td\u003e\n\u003ctd\u003e0020017366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Starter\u003c\/td\u003e\n\u003ctd\u003e0020019397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Advanced\u003c\/td\u003e\n\u003ctd\u003e0020105873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.6\u003c\/td\u003e\n\u003ctd\u003e0020102324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.30 Tempering hose 800 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020108012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.31 Tempering hose 1200 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020110278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.32 Tempering hose 1600 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020113271\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 6000.1 Water protect, 100 ml\u003c\/td\u003e\n\u003ctd\u003e0020014031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020104311.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991786557510,"sku":"0020104311","price":3136.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-hrc-2-lite-cooling-and-heating-circulator.jpg?v=1794350675","url":"https:\/\/bielengineering.com\/products\/ika-hrc-2-lite-cooling-and-heating-circulator","provider":"BIEL engineering","version":"1.0","type":"link"}