{"product_id":"ika-hbc-10-control-heating-bath-circulator-7-10-l","title":"IKA HBC 10 control Heating bath circulator, 7-10 l","description":"\u003cp\u003eThe HBC 10 control heated bath circulator heats up to a max. temperature of 250 °C. It has a high quality stainless steel bath with a volume of 7.5 – 10.5 liters. The TFT display is in color and illustrates all relevant parameters. With just one key, the internal temperature regulation can be switched to external temperature regulation. The large surface of the radiator allows for an optimum heat exchange and a gentle heating process of the medium. Push and turn buttons allow for intuitive menu navigation. The menu comes in different languages. The bath has a front drain valve for safe emptying. In order to drain the system, a hose is connected so there is no direct contact with the tempering fluid. With the unique WiCo Wireless Controller, the unit can be operated from a distance of up to 10 meters\/3 ft.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature range: 20 – 250 °C\u003c\/li\u003e\n\u003cli\u003eTemperature accuracy: ± 0.1 K\u003c\/li\u003e\n\u003cli\u003eWireless controller (WiCo) enables safe operation, e.g. outside of a closed fume hood\u003c\/li\u003e\n\u003cli\u003eLarge easy to read TFT display for temperature, pump speed, filling level and safety temperature\u003c\/li\u003e\n\u003cli\u003ePowerful, speed controlled pressure\/suction pump\u003c\/li\u003e\n\u003cli\u003eIntegrated cooling coil\u003c\/li\u003e\n\u003cli\u003eAdjustable safety circuit\u003c\/li\u003e\n\u003cli\u003eSafety classification III (FL) according to DIN 12876\u003c\/li\u003e\n\u003cli\u003eElectronic timer function: 0 – 99 h 59 min\u003c\/li\u003e\n\u003cli\u003eVisual and acoustic safety warnings\u003c\/li\u003e\n\u003cli\u003eConnection of a magnetic valve possible\u003c\/li\u003e\n\u003cli\u003eUSB \/ RS 232 interface for PC control and documentation using labworldsoft®, as well as updating the device software through our website\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAppliance type\u003c\/th\u003e\n\u003ctd\u003eCirculation thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClass designation acc. DIN 12876\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentification according to DIN 12876\u003c\/th\u003e\n\u003ctd\u003eFL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat output\u003c\/th\u003e\n\u003ctd\u003e2500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature\u003c\/th\u003e\n\u003ctd\u003eroom temp. +10K @1000rpm - 250 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature min. (with external cooling)\u003c\/th\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature display\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature control\u003c\/th\u003e\n\u003ctd\u003ePID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature display\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety temperature display\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature stability DIN 12876\u003c\/th\u003e\n\u003ctd\u003e±0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection for ext. temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay for operation with ext. sensor\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet temperature resolution\u003c\/th\u003e\n\u003ctd\u003e±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function optical\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function acoustic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function excess temperature\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarning function insufficient temperature\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAdjustable safety circuit\u003c\/th\u003e\n\u003ctd\u003e0 - 260 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSub-level protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOver-level protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFilling volume\u003c\/th\u003e\n\u003ctd\u003e8 - 11 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump type\u003c\/th\u003e\n\u003ctd\u003ePressure- \/ suction pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump capacity adjustable\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump pressure max. (0 liters discharge flow)\u003c\/th\u003e\n\u003ctd\u003e0.61 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure pump (suction side) (0 liter flow)\u003c\/th\u003e\n\u003ctd\u003e0.45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow rate max. (0 bar back pressure)\u003c\/th\u003e\n\u003ctd\u003e31 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump connection\u003c\/th\u003e\n\u003ctd\u003eM16x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling coil connection\u003c\/th\u003e\n\u003ctd\u003eNW 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBath depth min.\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth bath opening\u003c\/th\u003e\n\u003ctd\u003e172 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDepth bath opening\u003c\/th\u003e\n\u003ctd\u003e82 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCalibration option\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTechnical data complies with the standard\u003c\/th\u003e\n\u003ctd\u003eDIN 12876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ON time\u003c\/th\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMulti-Interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm output (potential-free contact) max.\u003c\/th\u003e\n\u003ctd\u003e30 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm output (potential-free contact) max.\u003c\/th\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolenoid valve output\u003c\/th\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolenoid valve output max.\u003c\/th\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandby input\u003c\/th\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e275 x 456 x 506 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e18.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e2650 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHF.Si.20.250.50A\u003c\/td\u003e\n\u003ctd\u003e0020003521\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHF.Si.20.200.50\u003c\/td\u003e\n\u003ctd\u003e0020003520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUF.Si.N30.150.10LV\u003c\/td\u003e\n\u003ctd\u003e0020003518\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBath cleaner\u003c\/td\u003e\n\u003ctd\u003e0020004610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estainless steel surface cleaner\u003c\/td\u003e\n\u003ctd\u003e0020004611\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.20 Hose kit (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0002606700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.21 Hose kit insulated (2 pcs)\u003c\/td\u003e\n\u003ctd\u003e0020000988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PVC.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004568900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.SI.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.8 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.FKM.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0004569300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.8.R Tube\u003c\/td\u003e\n\u003ctd\u003e0020004612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH.PUR.12 Tube\u003c\/td\u003e\n\u003ctd\u003e0020004613\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO.8\u003c\/td\u003e\n\u003ctd\u003e0004569400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO.12\u003c\/td\u003e\n\u003ctd\u003e0004569500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMV 1 Magnetic valve\u003c\/td\u003e\n\u003ctd\u003e0020003763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO V 1 Closed pressure valve\u003c\/td\u003e\n\u003ctd\u003e0020000249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBall valve M16x1\u003c\/td\u003e\n\u003ctd\u003e0020004620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emechanic fluid level controller\u003c\/td\u003e\n\u003ctd\u003e0020004618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eelbow tube 90°\u003c\/td\u003e\n\u003ctd\u003e0025001212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 6 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 8 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 12 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004889\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOlive for DN 10 hoses (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004569\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 1\/2 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter NPT 3\/4 (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003elock nut (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004583\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estopper (2 pcs.)\u003c\/td\u003e\n\u003ctd\u003e0020004584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWH10 WiCo Holder\u003c\/td\u003e\n\u003ctd\u003e0020000984\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT 100.30 Temperature sensor\u003c\/td\u003e\n\u003ctd\u003e0004284700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT 100 extension (LEMO)\u003c\/td\u003e\n\u003ctd\u003e0020004629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Pro\u003c\/td\u003e\n\u003ctd\u003e0020017366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Starter\u003c\/td\u003e\n\u003ctd\u003e0020019397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.30 Tempering hose 800 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020108012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.31 Tempering hose 1200 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020110278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLT 5.32 Tempering hose 1600 mm, 2 pcs\u003c\/td\u003e\n\u003ctd\u003e0020113271\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0004137000.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991786131526,"sku":"0004137000","price":5512.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-hbc-10-control-heating-bath-circulator-7-10-l.jpg?v=1794350666","url":"https:\/\/bielengineering.com\/products\/ika-hbc-10-control-heating-bath-circulator-7-10-l","provider":"BIEL engineering","version":"1.0","type":"link"}