{"product_id":"ika-c-200-calorimeter","title":"IKA C 200 Calorimeter","description":"\u003cp\u003eC 200-System consists of the following components:\u003cbr\u003eMeasuring cell C 200\u003cbr\u003eDecomposition vessel C 5010\u003cbr\u003eOxygen filling station C 248\u003cbr\u003eConsumables for calibrations and installation\u003c\/p\u003e\n\u003cp\u003eSpace-saving and low cost combustion calorimeter for determing gross calorific values of liquid and solid samples.\u003c\/p\u003e\n\u003cp\u003eValidation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.\u003c\/p\u003e\n\u003cp\u003eSuitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses..\u003c\/p\u003e\n\u003cp\u003eManual handling for water and oxygen filling.\u003c\/p\u003e\n\u003cp\u003eFour different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks.\u003c\/p\u003e\n\u003cp\u003eClear and easily explained display which is simply to use .\u003c\/p\u003e\n\u003cp\u003eWith an external power pack, \"world tension useable\" from 100 - 240 V AC, 50\/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage.\u003c\/p\u003e\n\u003cp\u003eFriendly in aftersales\u003c\/p\u003e\n\u003cp\u003eManual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute.\u003cbr\u003eAll calculations have to be done manually.\u003cbr\u003eAt the other three modes ignition and calculation of the gross calorific value will be done automatically.\u003cbr\u003eThe gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually.\u003c\/p\u003e\n\u003cp\u003eThe modes have different measuring times:\u003cbr\u003eIsoperibolic: approx: 17 min.\u003cbr\u003eDynamic : approx. 8 min\u003cbr\u003eManual : approx. 17 min\u003cbr\u003e(depend on the operator)\u003cbr\u003eTime controlled : 14 min\u003c\/p\u003e\n\u003cp\u003eThe decomposition vessel can be equiped in to use an combustible crucibles C 14\u003cbr\u003e(accessory C 5010.4 attachment is neessary)\u003c\/p\u003e\n\u003cp\u003eUser-friendly software C 6040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible\u003cbr\u003eUp to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory)\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring range max.\u003c\/th\u003e\n\u003ctd\u003e40000 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring mode dynamic 25°C\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring mode isoperibol 25°C\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring time dynamic approx.\u003c\/th\u003e\n\u003ctd\u003e8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring time isoperibol approx.\u003c\/th\u003e\n\u003ctd\u003e17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReproducibility dynamic (1g benzoic acid NBS39i)\u003c\/th\u003e\n\u003ctd\u003e0.1 %RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReproducibility isoperibol (1g benzoic acid NBS39i)\u003c\/th\u003e\n\u003ctd\u003e0.1 %RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking temperature max.\u003c\/th\u003e\n\u003ctd\u003e25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measurement resolution\u003c\/th\u003e\n\u003ctd\u003e0.0001 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface printer\u003c\/th\u003e\n\u003ctd\u003eCentronix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface PC\u003c\/th\u003e\n\u003ctd\u003eRS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOxygen filling\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDegasification\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDecomposition detection\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDecomposition vessel C 5010\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to DIN 51900\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to DIN EN ISO 1716\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to DIN EN ISO 18125\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to DIN EN 15400\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to DIN CEN TS 14918\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to DIN CEN\/TS 16023\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to DIN SPEC 19524\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to ASTM D240\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to ASTM D4809\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to ASTM D5468\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to ASTM D5865\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to ISO 1928\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorks according to GOST Certified\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e400 x 400 x 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e28.912 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e20 - 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification ANA\u003c\/td\u003e\n\u003ctd\u003e0010006578\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 or 3.1) ANA\u003c\/td\u003e\n\u003ctd\u003e0010065808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) ANA\u003c\/td\u003e\n\u003ctd\u003e0010010801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation ANA\u003c\/td\u003e\n\u003ctd\u003e0010006582\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate ANA\u003c\/td\u003e\n\u003ctd\u003e0010006580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 5010 Decomposition vessel, standard\u003c\/td\u003e\n\u003ctd\u003e0020128010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 5010 Decomposition vessel, standard\u003c\/td\u003e\n\u003ctd\u003e0007114000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 5010.4 Attachment for combustible crucible C14\u003c\/td\u003e\n\u003ctd\u003e0003016900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 5010.5 Crucible holder big\u003c\/td\u003e\n\u003ctd\u003e0003055900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 5030 Venting station\u003c\/td\u003e\n\u003ctd\u003e0007198000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 21 Pelleting press\u003c\/td\u003e\n\u003ctd\u003e0001605300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 200.1 Measuring cup 2000 ml\u003c\/td\u003e\n\u003ctd\u003e0003548900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 29 Pressure gauge, oxygen (DIN 477)\u003c\/td\u003e\n\u003ctd\u003e0000750200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 710.4 Cotton thread, cut to length\u003c\/td\u003e\n\u003ctd\u003e0001483700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 5010.3 Ignition wire, spare\u003c\/td\u003e\n\u003ctd\u003e0007122800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 4 Quartz dish\u003c\/td\u003e\n\u003ctd\u003e0001695500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 5 Set of VA combustion crucibles\u003c\/td\u003e\n\u003ctd\u003e0001749500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 6 Quartz crucible, big\u003c\/td\u003e\n\u003ctd\u003e0000355100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 710.2 Set of VA combustion crucibles\u003c\/td\u003e\n\u003ctd\u003e0001483500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 723 Benzoic acid, blister package\u003c\/td\u003e\n\u003ctd\u003e0003243000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 723 Benzoic acid BIG Package\u003c\/td\u003e\n\u003ctd\u003e0003717400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 43 Benzoic acid NBS 39j\u003c\/td\u003e\n\u003ctd\u003e0000750600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 9 Gelatine capsules\u003c\/td\u003e\n\u003ctd\u003e0000749900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 10 Acetobutyrate capsules\u003c\/td\u003e\n\u003ctd\u003e0000750000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 12 A Combustion bags 70 x 40 mm\u003c\/td\u003e\n\u003ctd\u003e0002201500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 12 Combustion bags 40 x 35 mm\u003c\/td\u003e\n\u003ctd\u003e0002201400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 14 Combustible crucible\u003c\/td\u003e\n\u003ctd\u003e0007224500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 15 Paraffin strips\u003c\/td\u003e\n\u003ctd\u003e0003131100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 16 Parafilm\u003c\/td\u003e\n\u003ctd\u003e0003801100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 17 Paraffin\u003c\/td\u003e\n\u003ctd\u003e0003801200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 26 Prep Stand\u003c\/td\u003e\n\u003ctd\u003e0008804000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 200.RC Set of hoses\u003c\/td\u003e\n\u003ctd\u003e0020010835\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 6000.1 Water protect, 100 ml\u003c\/td\u003e\n\u003ctd\u003e0020014031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC 6040 CalWin\u003c\/td\u003e\n\u003ctd\u003e0004040500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0008802500.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991772991558,"sku":"0008802500","price":21921.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-c-200-calorimeter.jpg?v=1794350290","url":"https:\/\/bielengineering.com\/products\/ika-c-200-calorimeter","provider":"BIEL engineering","version":"1.0","type":"link"}