IKA C 1 Package 3/10 Calorimeter
The C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.
- With the C 1 package 3/10 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature < 21 °C: measuring mode 22 °C/ water temperature > 21 °C: measuring mode 30 °C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained.
- Scope of delivery
We reply to quote requests within one working day.
- Supplied through our manufacturer partnerships
- Installation, training and calibration on request
Overview
What this IKA unit gives you, taken from the manufacturer data we hold on file.
- With the C 1 package 3/10 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature < 21 °C: measuring mode 22 °C/ water temperature > 21 °C: measuring mode 30 °C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained.
- Scope of delivery
- C 1 calorimeter
- C 1.10 combustion chamber
- C 1.20 water heater
- The scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations.
- Technical data Measuring range max. 40000 J Measuring mode adiabatic 22°C no Measuring mode dynamic 22°C no Measuring mode isoperibol 22°C no Measuring mode static jacket 22°C yes Measuring mode adiabatic 25°C no Measuring mode dynamic 25°C no Measuring mode isoperibol 25°C no Measuring mode static jacket 25°C no Measuring mode adiabatic 30°C no Measuring mode dynamic 30°C no Measuring mode isoperibol 30°C no Measuring mode static jacket 30°C yes Measuring mode double dry (ISO 1928) no Measurements/h static jacket 4 Reproducibility static jacke (1g benzoic acid NBS39i) 0.15 %RSD Touchscreen no Working temperature 20 - 30 °C Temperature measurement resolution 0.0001 K Cooling medium temperature 18 - 29 °C Cooling medium permissible operating pressure 1.5 bar Cooling medium tap water Type of cooling flow Flow rate 50 - 60 l/h Rec. flow rate at 18°C 55 l/h Oxygen operating pressure max. 40 bar Interface scale RS232 Interface printer RS232 Interface PC RS232 Interface test rack no Interface ext. monitor no Interface ext. keyboard no Oxygen filling yes Degasification yes Decomposition detection no Decomposition vessel C 5010 no Decomposition vessel C 5012 no Decomposition vessel C 7010 no Decomposition vessel C 7012 no Decomposition vessel C 6010 no Decomposition vessel C 6012 no Decomposition vessel C 62 no Decomposition vessel integrated yes Analysis according to DIN 51900 yes Analysis according to ASTM D240 no Analysis according to ASTM D4809 no Analysis according to ASTM D1989 no Analysis according to ASTM D5468 no Analysis according to ASTM D5865 no Analysis according to ASTM E711 no Analysis according to ISO 1928 yes Analysis according to BS 1016 no Dimensions (W x H x D) 290 x 280 x 300 mm Weight 15 kg Permissible ambient temperature 5 - 40 °C Permissible relative humidity 80 % Protection class according to DIN EN 60529 IP 20 RS 232 interface yes USB interface yes Analog output no Voltage 100 - 240 V Frequency 50/60 Hz Power input 120 W Accessories Accessory Article no. Factory Calibration Certificate ANA 0010006580 General Certificates (2.2 or 3.1) ANA 0010065808 Qualification Execution (IQ/OQ) ANA 0010010801 IQ/OQ Documentation ANA 0010006582 Documents for qualification ANA 0010006578 C 1.10 Combustion chamber 0004500300 C 1.12 Combustion chamber, halogen resistant 0004500400 C 1.50 Dot matrix printer 0004500600 C 1.30 Venting station 0004500900 C 1.1012 Organizer 0004500700 C 1.101 Set of spare parts 0004502200 C 1.103 Ignition wire 0004579300 C 1.123 Ignition wire platinum 0004500200 C 27 Calorimeter preparation set 0004579700 C 29 Pressure gauge, oxygen (DIN 477) 0000750200 RC 2 basic 0004171000 RC 2 control 0004173000 KV 600 NR cooling water supply 0020002143 C 21 Pelleting press 0001605300 C 5010.8 Crucible holder small 0004579800 C 5010.5 Crucible holder big 0003055900 C 710.4 Cotton thread, cut to length 0001483700 C 710.8 Cotton thread 0004579900 C 4 Quartz dish 0001695500 C 5 Set of VA combustion crucibles 0001749500 C 6 Quartz crucible, big 0000355100 C 710.2 Set of VA combustion crucibles 0001483500 C 9 Gelatine capsules 0000749900 C 10 Acetobutyrate capsules 0000750000 C 12 Combustion bags 40 x 35 mm 0002201400 C 12 A Combustion bags 70 x 40 mm 0002201500 C 15 Paraffin strips 0003131100 C 16 Parafilm 0003801100 C 17 Paraffin 0003801200 C 43 Benzoic acid NBS 39j 0000750600 C 723 Benzoic acid, blister package 0003243000 C 723 Benzoic acid BIG Package 0003717400 AOD 1.11 Control standard 0003044000 AOD 1.12 Control standard 0003080200 C 6000.1 Water protect, 100 ml 0020014031 C 1.20 Heater 0004501000 C 6040 CalWin 0004040500 Article no. 0010005635. Ask BIEL engineering for delivery time and a quote.
Delivery and support
Lead time depends on the manufacturer and the configuration, so we confirm it with your quote. Delivery, installation, operator training and calibration can all be included, and we will price them separately so you can see what each part costs.
Tell us the country you need it delivered to and we will quote transport and any documentation your institution requires.