Huber Unichiller P010w-H Recirculating Chiller, -20 to 100 °C
The Huber Unichiller P010w-H is a water-cooled recirculating chiller with the Pilot ONE controller for -20 to 100 °C. It offers 1.8 - 2.1 kW heating capacity, 1 kW cooling capacity at 15 °C and a pump delivering up to 25 l/min at 2.5 bar. Unichillers replace tap-water cooling with a closed circuit at constant temperature, pressure and flow, for removing process heat, cooling technical equipment or supplying a laboratory with cooling water. They are designed for continuous operation at ambient temperatures up to 40 °C.
- Temperature range
- -20 to 100 °C
- Temperature stability
- ±0.2 K
- Controller
- Pilot ONE
- Safety class
- III / FL
We reply to quote requests within one working day.
- Supplied through our manufacturer partnerships
- Installation, training and calibration on request
Overview
What this Huber unit gives you, taken from the manufacturer data we hold on file.
- Available with synthetic refrigerant (R-449A) and natural refrigerant (R-290).
- Features Environmentally-friendly, economic cooling solution
- High efficiency
- Precise temperature control
- Powerful circulation pump
- Robust stainless construction
- Reliable continuously operation with warning functions
- Easy to fill and empty
- Adjustable bypass, level indicator with sight glass and digital manometer
- Pilot ONE controller with 5.7" touchscreen
- 2 x USB (Host and Device), Ethernet and RS232 interfaces
- Specifications Synthetic refrigerant (R-449A) Natural refrigerant (R-290) Temperature range -20 to 100 °C -20 to 100 °C Temperature stability ±0.2 K ±0.2 K Controller Pilot ONE Pilot ONE Safety class III / FL III / FL Protection class IP20 IP20 Dimensions (W x D x H) 350 x 496 x 622 mm 350 x 496 x 622 mm Net weight 56 kg - Heating capacity 1.8 - 2.1 kW 1.8 - 2.1 kW Cooling capacity at 15 °C 1 kW 1 kW Cooling capacity at 0 °C 0.8 kW 0.8 kW Cooling capacity at -10 °C 0.5 kW 0.5 kW Cooling capacity at -20 °C 0.15 kW 0.15 kW Refrigeration machine water-cooled, CFC- and HCFC-free water-cooled, natural refrigerant Refrigerant 1st stage R-449A (A1, H280) R-290 (A3, H220) Refrigerant quantity 1st stage 0.2 kg - Pressure pump, max. 25 l/min; 2.5 bar 25 l/min; 2.5 bar Pump connection G3/4 male G3/4 male Pump speed adjustable no no Pump type B B Pump characteristics Pressure pump, speed not variable, manual bypass integrated Pressure pump, speed not variable, manual bypass integrated External sensor connection Pt100 Pt100 Digital interfaces Ethernet, USB (Host and Device), RS232 Ethernet, USB (Host and Device), RS232 Permissible ambient temperature 5 to 40 °C 5 to 40 °C Filling volume min. 3.8 l 3.8 l Expansion volume 1.7 l 1.7 l Cooling water connection G1/2 male G1/2 male Cooling water differential pressure min. 1 bar 1 bar Cooling water pressure max. 6 bar 6 bar Power supply 220-240 V 1~/2~ 50/60 Hz 220-240 V 1~/2~ 50/60 Hz Current consumption, max. 14.5 A - Fuse 16 A - Huber order no. 3050.0007.01 3050.0040.01 European version (220-240 V 1~/2~ 50/60 Hz). Other voltages on request.
- Price on request. Tell us your application and we send an offer.
Specifications
| Temperature range | -20 to 100 °C |
|---|---|
| Temperature stability | ±0.2 K |
| Controller | Pilot ONE |
| Safety class | III / FL |
| Protection class | IP20 |
| Dimensions (W x D x H) | 350 x 496 x 622 mm |
| Net weight | 56 kg |
| Heating capacity | 1.8 - 2.1 kW |
| Cooling capacity at 15 °C | 1 kW |
| Cooling capacity at 0 °C | 0.8 kW |
| Cooling capacity at -10 °C | 0.5 kW |
| Cooling capacity at -20 °C | 0.15 kW |
| Refrigeration machine | water-cooled, CFC- and HCFC-free |
| Refrigerant 1st stage | R-449A (A1, H280) |
| Refrigerant quantity 1st stage | 0.2 kg |
| Pressure pump, max. | 25 l/min; 2.5 bar |
| Pump connection | G3/4 male |
| Pump speed adjustable | no |
| Pump type | B |
| Pump characteristics | Pressure pump, speed not variable, manual bypass integrated |
| External sensor connection | Pt100 |
| Digital interfaces | Ethernet, USB (Host and Device), RS232 |
| Permissible ambient temperature | 5 to 40 °C |
| Filling volume min. | 3.8 l |
| Expansion volume | 1.7 l |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure min. | 1 bar |
| Cooling water pressure max. | 6 bar |
| Power supply | 220-240 V 1~/2~ 50/60 Hz |
| Current consumption, max. | 14.5 A |
| Fuse | 16 A |
| Price list note | Unichiller "P" Models: Circulating pumps with a high discharge pressure for applications with high pressure drops. |
| Huber order no. | 3050.0007.01 |
| Manufacturer | Huber |
| Part number | 3050.0007.01 |
Figures come from the manufacturer. Ask us if you need a value confirmed for your application.
Delivery and support
Lead time depends on the manufacturer and the configuration, so we confirm it with your quote. Delivery, installation, operator training and calibration can all be included, and we will price them separately so you can see what each part costs.
Tell us the country you need it delivered to and we will quote transport and any documentation your institution requires.