Huber Unichiller 070Tw-H Recirculating Chiller
The Huber Unichiller 070Tw-H is a water-cooled recirculating chiller with the Pilot ONE controller. It offers 2 kW heating capacity, 7 kW cooling capacity at 15 °C and a pump delivering up to 84 l/min at 5.6 bar. Unichillers replace tap-water cooling with a closed circuit at constant temperature, pressure and flow, for removing process heat, cooling technical equipment or supplying a laboratory with cooling water. They are designed for continuous operation at ambient temperatures up to 40 °C.
- Temperature range
- -10 to 100 °C
- Temperature stability
- ±0.2 K
- Controller
- Pilot ONE
- Safety class
- III / FL
We reply to quote requests within one working day.
- Supplied through our manufacturer partnerships
- Installation, training and calibration on request
Overview
What this Huber unit gives you, taken from the manufacturer data we hold on file.
- Available with synthetic refrigerant (R-449A) and natural refrigerant (R-290).
- Features Environmentally-friendly, economic cooling solution
- High efficiency
- Precise temperature control
- Powerful circulation pump
- Intelligent energy management
- Reliable continuously operation with warning functions
- Pilot ONE controller with 5.7" touchscreen
- Digital filling level indicator
- 2 x USB (Host and Device), Ethernet and RS232 interfaces
- Heater options available
- Specifications Synthetic refrigerant (R-449A) Natural refrigerant (R-290) Temperature range -10 to 100 °C -20 to 100 °C Temperature stability ±0.2 K ±0.2 K Controller Pilot ONE Pilot ONE Safety class III / FL III / FL Protection class IP20 IP20 Dimensions (W x D x H) 600 x 600 x 1450 mm 640 x 660 x 1606 mm Net weight 212 kg - Heating capacity 2 kW 2 kW Cooling capacity at 15 °C 7 kW 7 kW Cooling capacity at 0 °C 4.2 kW 4.2 kW Cooling capacity at -10 °C 2.5 kW 2.5 kW Refrigeration machine water-cooled, CFC- and HCFC-free water-cooled, natural refrigerant Refrigerant 1st stage R-449A (A1, H280) R-290 (A3, H220) Refrigerant quantity 1st stage 1.35 kg - Pressure pump, max. 84 l/min; 5.6 bar 84 l/min; 5.6 bar Pump connection G1 1/4 male G1 1/4 male Pump speed adjustable no no Pump type C3 C3 Pump characteristics Pressure pump, speed not variable Pressure pump, speed not variable External sensor connection Pt100 Pt100 Digital interfaces Ethernet, USB (Host and Device), RS232 Ethernet, USB (Host and Device), RS232 Permissible ambient temperature 5 to 40 °C 5 to 40 °C Filling volume min. 5.9 l 5.9 l Expansion volume 7.5 l 7.5 l Cooling water connection G1/2 male G1/2 male Cooling water consumption at 15°C, flow -10°C 264 l/h - Cooling water consumption at 15°C, flow 0°C 330 l/h - Cooling water consumption at 15°C, flow 15°C 474 l/h - Cooling water differential pressure min. 1.5 bar 1.5 bar Cooling water pressure max. 6 bar 6 bar Power supply 400 V 3~ 50 Hz 400 V 3~ 50 Hz Current consumption, max. 12 A - Fuse 3x16A - Huber order no. 3016.0032.01 3016.0052.01 European version (400 V 3~ 50 Hz). Other voltages on request.
- Price on request. Tell us your application and we send an offer.
Specifications
| Temperature range | -10 to 100 °C |
|---|---|
| Temperature stability | ±0.2 K |
| Controller | Pilot ONE |
| Safety class | III / FL |
| Protection class | IP20 |
| Dimensions (W x D x H) | 600 x 600 x 1450 mm |
| Net weight | 212 kg |
| Heating capacity | 2 kW |
| Cooling capacity at 15 °C | 7 kW |
| Cooling capacity at 0 °C | 4.2 kW |
| Cooling capacity at -10 °C | 2.5 kW |
| Refrigeration machine | water-cooled, CFC- and HCFC-free |
| Refrigerant 1st stage | R-449A (A1, H280) |
| Refrigerant quantity 1st stage | 1.35 kg |
| Pressure pump, max. | 84 l/min; 5.6 bar |
| Pump connection | G1 1/4 male |
| Pump speed adjustable | no |
| Pump type | C3 |
| Pump characteristics | Pressure pump, speed not variable |
| External sensor connection | Pt100 |
| Digital interfaces | Ethernet, USB (Host and Device), RS232 |
| Permissible ambient temperature | 5 to 40 °C |
| Filling volume min. | 5.9 l |
| Expansion volume | 7.5 l |
| Cooling water connection | G1/2 male |
| Cooling water consumption at 15°C, flow -10°C | 264 l/h |
| Cooling water consumption at 15°C, flow 0°C | 330 l/h |
| Cooling water consumption at 15°C, flow 15°C | 474 l/h |
| Cooling water differential pressure min. | 1.5 bar |
| Cooling water pressure max. | 6 bar |
| Power supply | 400 V 3~ 50 Hz |
| Current consumption, max. | 12 A |
| Fuse | 3x16A |
| Huber order no. | 3016.0032.01 |
| Manufacturer | Huber |
| Part number | 3016.0032.01 |
Figures come from the manufacturer. Ask us if you need a value confirmed for your application.
Delivery and support
Lead time depends on the manufacturer and the configuration, so we confirm it with your quote. Delivery, installation, operator training and calibration can all be included, and we will price them separately so you can see what each part costs.
Tell us the country you need it delivered to and we will quote transport and any documentation your institution requires.
Ask about this item
Your quote list
This item is ready to send. Add anything else you need from the related items below and it goes out as one request.
Not sure which model fits your work?
Send us your samples, throughput and the standard you work to. We will come back with the model that fits and a written quote.