Huber CC-905w Refrigerated Heating Circulator, -90 to 200 °C
The Huber CC-905w is a refrigerated heating bath circulator with the Pilot ONE controller for -90 to 200 °C. It offers 3 kW heating capacity, 2 kW cooling capacity at 20 °C, a pump delivering up to 25 l/min at 0.7 bar and 26 l bath volume. It controls externally connected applications such as jacketed reaction vessels, photometers, refractometers or viscometers, and objects can also be tempered directly in its bath. Additional controller functions can be activated later with an E-grade code.
- Temperature range
- -90 to 200 °C
- Temperature stability
- ±0.02 K
- Controller
- Pilot ONE
- Safety class
- III / FL
We reply to quote requests within one working day.
- Supplied through our manufacturer partnerships
- Installation, training and calibration on request
Overview
What this Huber unit gives you, taken from the manufacturer data we hold on file.
- Available with synthetic refrigerant (R-452A / R-508B) and natural refrigerant (R-1270 / R-170).
- Features Pilot ONE controller with Plug & Play technology
- Precise temperature control
- 5.7“ touchscreen and comfortable menu navigation
- Overtemperature and low level protection
- Safety class III/FL (DIN 12876)
- Powerful pressure/suction pump
- Programmer with calendar and clock functions
- 2-point calibration
- Pt100 sensor connection
- Specifications Synthetic refrigerant (R-452A / R-508B) Natural refrigerant (R-1270 / R-170) Temperature range -90 to 200 °C -90 to 200 °C Temperature stability ±0.02 K ±0.02 K Controller Pilot ONE Pilot ONE Safety class III / FL III / FL Protection class IP20 IP20 Dimensions (W x D x H) 605 x 706 x 1136 mm 605 x 706 x 1136 mm Net weight 175 kg - Heating capacity 3 kW 3 kW Cooling capacity at 200 °C 2.5 kW 2.5 kW Cooling capacity at 100 °C 2 kW 2 kW Cooling capacity at 20 °C 2 kW 2 kW Cooling capacity at 0 °C 2 kW 2 kW Cooling capacity at -20 °C 1.9 kW 1.9 kW Cooling capacity at -40 °C 1.7 kW 1.7 kW Cooling capacity at -60 °C 1 kW 1 kW Cooling capacity at -80 °C 0.34 kW 0.34 kW Cooling capacity at -90 °C 0.13 kW 0.13 kW Refrigeration machine water-cooled, CFC- and HCFC-free water-cooled, natural refrigerant Refrigerant 1st stage R-452A (A1, H280) R-1270 (A3, H220) Refrigerant quantity 1st stage 0.9 kg - Refrigerant 2nd stage R-508B (A1, H280) R-170 (A3, H220) Refrigerant quantity 2nd stage 0.43 kg - Pressure pump, max. 25 l/min; 0.7 bar 25 l/min; 0.7 bar Suction pump, max. 18.5 l/min; 0.4 bar 18.5 l/min; 0.4 bar Pump connection M16x1 male M16x1 male Max. permissible viscosity 50 mm²/s 50 mm²/s Pump speed adjustable yes yes Pump characteristics Pressure and suction pump, variable speed Pressure and suction pump, variable speed External sensor connection Pt100 Pt100 Digital interfaces Ethernet, USB (Host and Device), RS232 Ethernet, USB (Host and Device), RS232 Permissible ambient temperature 5 to 40 °C 5 to 40 °C Bath opening W x D / bath depth 260 x 260 / 200 mm 260 x 260 / 200 mm Bath volume 26 l 26 l Filling volume min. 19 l 19 l Cooling water connection G1/2 male G1/2 male Cooling water consumption at 15°C, flow 0°C 170 l/h - Cooling water differential pressure min. 3 bar 3 bar Cooling water pressure max. 6 bar 6 bar Power supply 400 V 3~N 50 Hz 400 V 3~N 50 Hz Current consumption, max. 13 A - Fuse 3x16A - Huber order no. 2027.0002.01 2027.0008.01 European version (400 V 3~N 50 Hz). Other voltages on request.
- Price on request. Tell us your application and we send an offer.
Specifications
| Temperature range | -90 to 200 °C |
|---|---|
| Temperature stability | ±0.02 K |
| Controller | Pilot ONE |
| Safety class | III / FL |
| Protection class | IP20 |
| Dimensions (W x D x H) | 605 x 706 x 1136 mm |
| Net weight | 175 kg |
| Heating capacity | 3 kW |
| Cooling capacity at 200 °C | 2.5 kW |
| Cooling capacity at 100 °C | 2 kW |
| Cooling capacity at 20 °C | 2 kW |
| Cooling capacity at 0 °C | 2 kW |
| Cooling capacity at -20 °C | 1.9 kW |
| Cooling capacity at -40 °C | 1.7 kW |
| Cooling capacity at -60 °C | 1 kW |
| Cooling capacity at -80 °C | 0.34 kW |
| Cooling capacity at -90 °C | 0.13 kW |
| Refrigeration machine | water-cooled, CFC- and HCFC-free |
| Refrigerant 1st stage | R-452A (A1, H280) |
| Refrigerant quantity 1st stage | 0.9 kg |
| Refrigerant 2nd stage | R-508B (A1, H280) |
| Refrigerant quantity 2nd stage | 0.43 kg |
| Pressure pump, max. | 25 l/min; 0.7 bar |
| Suction pump, max. | 18.5 l/min; 0.4 bar |
| Pump connection | M16x1 male |
| Max. permissible viscosity | 50 mm²/s |
| Pump speed adjustable | yes |
| Pump characteristics | Pressure and suction pump, variable speed |
| External sensor connection | Pt100 |
| Digital interfaces | Ethernet, USB (Host and Device), RS232 |
| Permissible ambient temperature | 5 to 40 °C |
| Bath opening W x D / bath depth | 260 x 260 / 200 mm |
| Bath volume | 26 l |
| Filling volume min. | 19 l |
| Cooling water connection | G1/2 male |
| Cooling water consumption at 15°C, flow 0°C | 170 l/h |
| Cooling water differential pressure min. | 3 bar |
| Cooling water pressure max. | 6 bar |
| Power supply | 400 V 3~N 50 Hz |
| Current consumption, max. | 13 A |
| Fuse | 3x16A |
| Huber order no. | 2027.0002.01 |
| Manufacturer | Huber |
| Part number | 2027.0002.01 |
Figures come from the manufacturer. Ask us if you need a value confirmed for your application.
Delivery and support
Lead time depends on the manufacturer and the configuration, so we confirm it with your quote. Delivery, installation, operator training and calibration can all be included, and we will price them separately so you can see what each part costs.
Tell us the country you need it delivered to and we will quote transport and any documentation your institution requires.
Ask about this item
Your quote list
This item is ready to send. Add anything else you need from the related items below and it goes out as one request.
Not sure which model fits your work?
Send us your samples, throughput and the standard you work to. We will come back with the model that fits and a written quote.