MultiKjel
Dimensions (W x D x H) 320 x 400 x 730 mm
Weight 23 kg
Connection voltage 220 - 240
Power consumption 2100 W
Frequency 50 - 60 Hz
IP Code IP20
Pollution degree 2
Overvoltage category II
Tap water pressure 1 - 10 bar
Tap water condition 1- 25°C
Tap water consumption approx 1.2 L/min
Approvals CE, CSA
Measuring range N 0.02 – 220 mg
Analysis time for 30 mg N (With Metrohm Eco Titrator without titrator preparation): 3.5 min
Analysis time for 200 mg N (With Metrohm Eco Titrator without titrator preparation): 5 min
Recovery N:
N: great than 98% with digestion process
N: great than 99.5% (direct distillation)
Measurement reproducibility (Direct distillation of 1 mg N absolute and 300 sec. distillation) less 0.8 %
Distillation capacity (100%) 40 mL/min
Distillation capacity (10%) 12.5 mL/min
Adjustable distillation power 10 - 100%
MaxAccuracy Mode (Compensation of power grid fluctuations) Yes
Distillate reproducibility (RSD) (At 300 seconds distillation time) less 1%
AutoDist Mode (Automatic detection of the condensation start) Yes
NaOH pump Yes
H2O pump Yes
Acid pump Yes
Dimensions (W x D x H) 320 x 400 x 730 mm
Weight 23 kg
Connection voltage 220 - 240
Power consumption 2100 W
Frequency 50 - 60 Hz
IP Code IP20
Pollution degree 2
Overvoltage category II
Tap water pressure 1 - 10 bar
Tap water condition 1- 25°C
Tap water consumption approx 1.2 L/min
Approvals CE, CSA
Measuring range N 0.02 – 220 mg
Analysis time for 30 mg N (With Metrohm Eco Titrator without titrator preparation): 3.5 min
Analysis time for 200 mg N (With Metrohm Eco Titrator without titrator preparation): 5 min
Recovery N:
N: great than 98% with digestion process
N: great than 99.5% (direct distillation)
Measurement reproducibility (Direct distillation of 1 mg N absolute and 300 sec. distillation) less 0.8 %
Distillation capacity (100%) 40 mL/min
Distillation capacity (10%) 12.5 mL/min
Adjustable distillation power 10 - 100%
MaxAccuracy Mode (Compensation of power grid fluctuations) Yes
Distillate reproducibility (RSD) (At 300 seconds distillation time) less 1%
AutoDist Mode (Automatic detection of the condensation start) Yes
NaOH pump Yes