{"title":"Vacuum Pumps \u0026 Controllers","description":"\u003cp\u003eLaboratory vacuum pumps and vacuum controllers. Request a quote from BIEL engineering.\u003c\/p\u003e","products":[{"product_id":"ika-vacstar-control-membrane-vacuum-pump","title":"IKA VACSTAR control Membrane vacuum pump","description":"\u003cp\u003eSeparation, filtration, removal: The VACSTAR dry 4-chamber membrane vacuum pump is powerful, resistant to chemicals and low-maintenance. VACSTAR control is the ideal system with its integrated vacuum controller and removable display. The controller offers a suitable mode for the desired process: from automatic to manual operation, right through to pumping or an evacuation and cleaning function.\u003c\/p\u003e\n\u003cp\u003eHigh-performance suction\u003cbr\u003eVACSTAR has an excellent suction performance, with its 22 l\/min at a minimum of 2 mbar.\u003c\/p\u003e\n\u003cp\u003eIntegrated vacuum controller with removable controller (WiCo)\u003cbr\u003eDepending on the application, you can easily select your operating mode either by using the intuitive operator menu or by remote control.\u003c\/p\u003e\n\u003cp\u003eFor additional safety for users and environment, we recommend using the VSE 1 vacuum safety emission condenser, which prevents solvents from being released into the room air. The VSE 1 is available as accessory.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1.32 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e22 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure without gas ballast\u003c\/th\u003e\n\u003ctd\u003e2 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction levels\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter suction side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter pressure side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas ballast valve\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e2 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog speed vacuum control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed adjustment\u003c\/th\u003e\n\u003ctd\u003eTurning knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1200 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure unit \/ scale\u003c\/th\u003e\n\u003ctd\u003embar, hPa, mmHg, Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor type\u003c\/th\u003e\n\u003ctd\u003eceramic Al2O3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure max. for pressure sensor\u003c\/th\u003e\n\u003ctd\u003e1.2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement range (absolute)\u003c\/th\u003e\n\u003ctd\u003e1 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement uncertainty\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum valve\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate trap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003eAl2O3, PTFE, FPM, PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ealu-cast coating \/ thermoplastic polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClean room qualified\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExplosion proofed\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode automatic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode manual\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode pump %\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode program\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e270 x 435 x 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80% (up to 31°C), decreasing linearly to max. 50 (@40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e140 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input standby\u003c\/th\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSW 1\u003c\/td\u003e\n\u003ctd\u003e0020015406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSE 1\u003c\/td\u003e\n\u003ctd\u003e0035001873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVH.SI.8 Vacuum hose\u003c\/td\u003e\n\u003ctd\u003e0020013886\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY hose connector 8 mm\u003c\/td\u003e\n\u003ctd\u003e0020010963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Starter\u003c\/td\u003e\n\u003ctd\u003e0020019397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Advanced\u003c\/td\u003e\n\u003ctd\u003e0020105873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Pro\u003c\/td\u003e\n\u003ctd\u003e0020017366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR-2.ST the High-Performer\u003c\/td\u003e\n\u003ctd\u003e0020013291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020109375.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991788621894,"sku":"0020109375","price":4863.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-control-membrane-vacuum-pump.jpg?v=1794350753"},{"product_id":"ika-vacstar-digital-membrane-vacuum-pump","title":"IKA VACSTAR digital Membrane vacuum pump","description":"\u003cp\u003eThe four-chamber membrane vacuum pump convinces with its high suction capacity, low space requirement and high serviceability. The setting of the parameters is carried out through a rotary-push button over a digital display showing current rpm.\u003cbr\u003eAutomated processes are controlled with the vacuum controller VC 10, which is available as an accessory. An analogue cable which is required for connecting pump and controller is included in the delivery of the pump. Additionally it is recommended to use the VSE 1 vacuum safety emmission. It prevents that solvents are released into ambient air.\u003cbr\u003eThe Vacstar digital is used for dry and oil-free applications in the laboratory. The membranes of the pump are particularly chemical resistant.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1.32 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e22 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure without gas ballast\u003c\/th\u003e\n\u003ctd\u003e2 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction levels\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter suction side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter pressure side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas ballast valve\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e2 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTwo-point control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog speed vacuum control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed adjustment\u003c\/th\u003e\n\u003ctd\u003eTurning knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1200 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate trap\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003eAl2O3; PTFE; FFPM; PPS; NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ealu-cast coating \/ thermoplastic polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClean room qualified\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExplosion proofed\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e150 x 375 x 370 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e11.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80% (up to 31°C), decreasing linearly to max. 50 (@40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog output\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e130 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input standby\u003c\/th\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSW 1\u003c\/td\u003e\n\u003ctd\u003e0020015406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.500 Stand pole\u003c\/td\u003e\n\u003ctd\u003e0035002702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSE 1\u003c\/td\u003e\n\u003ctd\u003e0035001873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVH.SI.8 Vacuum hose\u003c\/td\u003e\n\u003ctd\u003e0020013886\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Pro\u003c\/td\u003e\n\u003ctd\u003e0020017366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabworldsoft® 6 Starter\u003c\/td\u003e\n\u003ctd\u003e0020019397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR-2.ST the High-Performer\u003c\/td\u003e\n\u003ctd\u003e0020013291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10 Vacuum controller\u003c\/td\u003e\n\u003ctd\u003e0020005132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY hose connector 8 mm\u003c\/td\u003e\n\u003ctd\u003e0020010963\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020016236.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991788654662,"sku":"0020016236","price":3036.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-digital-membrane-vacuum-pump.jpg?v=1794350756"},{"product_id":"ika-vc-10-lite-vacuum-controller","title":"IKA VC 10 lite Vacuum controller","description":"\u003cp\u003eSpeed-controlled, universal vacuum controller for controlled evacuation of air (gas) from laboratory equipment, as well as for classical separation, filtration or drying tasks in the laboratory. The controller is ready-to-use in numerous applications and can be easily installed.\u003c\/p\u003e\n\u003cp\u003eVC 10 lite is only compatible with the vacuum pump VACSTAR digital. A cable connection between pump and controller is required.\u003cbr\u003eManual and programmable mode available.\u003c\/p\u003e\n\u003cp\u003eFeatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eValve cleaning function for long service life\u003c\/li\u003e\n\u003cli\u003eHigh energy efficiency thanks to device-to-device communication: control of the circulator by connecting the vacuum controller with PC 1.3 data cable (available as accessory)\u003c\/li\u003e\n\u003cli\u003eIntegrated ventilation valve for simple pressure equalization and aeration with inert gas after process completion\u003c\/li\u003e\n\u003cli\u003eVENT short key button allows pressure equalization during a running process\u003c\/li\u003e\n\u003cli\u003eProgram function: up to ten user-defined programs can be saved, with up to ten pressure\/time sequences\u003c\/li\u003e\n\u003cli\u003eUSB \/ RS232 interfaces for connection with the laboratory software labworldsoft®\u003c\/li\u003e\n\u003cli\u003eElectronic control system for improved process efficiency and higher solvent recovery rate\u003c\/li\u003e\n\u003cli\u003eHigh energy efficiency thanks to device-to-device communication (vacuum controller to recirculating chiller)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor additional safety for users and environment, the use of the VSE 1 vacuum safety emission condenser is recommended, which prevents solvents from being released into the room air. The VSE 1 is available as an accessory.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter suction side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter pressure side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter venting side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e1 - 1050 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTwo-point control\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog speed vacuum control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure unit \/ scale\u003c\/th\u003e\n\u003ctd\u003embar, hPa, mmHg, Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor type\u003c\/th\u003e\n\u003ctd\u003eceramic Al2O3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure max. for pressure sensor\u003c\/th\u003e\n\u003ctd\u003e1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement range (absolute)\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement uncertainty\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedium temperature (gas)\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum valve\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate trap\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measuring range max.\u003c\/th\u003e\n\u003ctd\u003e200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measurement resolution\u003c\/th\u003e\n\u003ctd\u003e1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy of temperature measurement\u003c\/th\u003e\n\u003ctd\u003e±1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTime setting min.\u003c\/th\u003e\n\u003ctd\u003e1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTime setting max.\u003c\/th\u003e\n\u003ctd\u003e6000 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum speed control interface\u003c\/th\u003e\n\u003ctd\u003eVACSTAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003eAl2O3, PTFE, FPM, PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClean room qualified\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExplosion proofed\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFastening\u003c\/th\u003e\n\u003ctd\u003estand \/ clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFastening diameter\u003c\/th\u003e\n\u003ctd\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode manual\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode program\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGraph function\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum leakage test\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e95 x 150 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.284 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog output\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input standby\u003c\/th\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDC Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.500 Stand pole\u003c\/td\u003e\n\u003ctd\u003e0035002702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.300 Check valve\u003c\/td\u003e\n\u003ctd\u003e0020011105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.400 Stand\u003c\/td\u003e\n\u003ctd\u003e0035001735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT 1000.60 Temperature sensor, stainless steel\u003c\/td\u003e\n\u003ctd\u003e0003516800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVH.SI.8 Vacuum hose\u003c\/td\u003e\n\u003ctd\u003e0020013886\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC 1.3 Cable\u003c\/td\u003e\n\u003ctd\u003e0025005322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSE 1\u003c\/td\u003e\n\u003ctd\u003e0035001873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR-2.ST the High-Performer\u003c\/td\u003e\n\u003ctd\u003e0020013291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020111998.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991788916806,"sku":"0020111998","price":1081.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vc-10-lite-vacuum-controller.jpg?v=1794350759"},{"product_id":"ika-vc-10-pro-vacuum-controller","title":"IKA VC 10 pro Vacuum controller","description":"\u003cp\u003eValve-controlled, universal vacuum controller for controlled evacuation of air (gas) from laboratory equipment, as well as for classical separation, filtration or drying tasks in the laboratory. The controller is ready-to-use in numerous applications and can be easily installed.\u003c\/p\u003e\n\u003cp\u003eVC 10 pro can be used with all standard vacuum sources. The use of multiple controllers with one vacuum source is possible.\u003c\/p\u003e\n\u003cp\u003eFeatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/off regulation of multiple vacuum sources\u003c\/li\u003e\n\u003cli\u003eAutomatic boiling point detection\u003c\/li\u003e\n\u003cli\u003eIntegrated solvent library: Helps to set the correct parameters for example in evaporation processes with rotary evaporators\u003c\/li\u003e\n\u003cli\u003eGraph function\u003c\/li\u003e\n\u003cli\u003eConnection for external temperature sensor: temperature value is shown on display\u003c\/li\u003e\n\u003cli\u003eValve cleaning function for long service life\u003c\/li\u003e\n\u003cli\u003eIntegrated ventilation valve for simple pressure equalization and aeration with inert gas after process completion\u003c\/li\u003e\n\u003cli\u003eVENT short key button allows pressure equalization during a running process\u003c\/li\u003e\n\u003cli\u003eProgram function: up to ten user-defined programs can be saved, with up to ten pressure\/time sequences\u003c\/li\u003e\n\u003cli\u003eUSB \/ RS232 interfaces for connection with the laboratory software labworldsoft®\u003c\/li\u003e\n\u003cli\u003eElectronic control system for improved process efficiency and higher solvent recovery rate\u003c\/li\u003e\n\u003cli\u003eHigh energy efficiency thanks to device-to-device communication (vacuum controller to recirculating chiller)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor additional safety for users and environment, the use of the VSE 1 vacuum safety emission condenser is recommended, which prevents solvents from being released into the room air. The VSE 1 is available as an accessory.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter suction side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter pressure side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection diameter venting side\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e1 - 1050 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTwo-point control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog speed vacuum control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure unit \/ scale\u003c\/th\u003e\n\u003ctd\u003embar, hPa, mmHg, Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum sensor type\u003c\/th\u003e\n\u003ctd\u003eceramic Al2O3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure max. for pressure sensor\u003c\/th\u003e\n\u003ctd\u003e1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement range (absolute)\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement uncertainty\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedium temperature (gas)\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate trap\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection for ext. temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature unit\u003c\/th\u003e\n\u003ctd\u003e°C \/ °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measuring range\u003c\/th\u003e\n\u003ctd\u003e-10 - 200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature measurement resolution\u003c\/th\u003e\n\u003ctd\u003e1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy of temperature measurement\u003c\/th\u003e\n\u003ctd\u003e±1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTime setting min.\u003c\/th\u003e\n\u003ctd\u003e1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTime setting max.\u003c\/th\u003e\n\u003ctd\u003e6000 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum speed control interface\u003c\/th\u003e\n\u003ctd\u003eVACSTAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003eAl2O3, PTFE, FPM, PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClean room qualified\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExplosion proofed\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFastening\u003c\/th\u003e\n\u003ctd\u003estand \/ clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFastening diameter\u003c\/th\u003e\n\u003ctd\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode automatic\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode manual\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode pump %\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode program\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGraph function\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum leakage test\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e95 x 150 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible relative humidity\u003c\/th\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog output\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input standby\u003c\/th\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDC Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eArticle no.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments for qualification LAB\u003c\/td\u003e\n\u003ctd\u003e0010006577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration Certificate LAB\u003c\/td\u003e\n\u003ctd\u003e0010006579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIQ\/OQ Documentation LAB\u003c\/td\u003e\n\u003ctd\u003e0010006581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Certificates (2.2 \/ 3.1) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualification Execution (IQ\/OQ) LAB\u003c\/td\u003e\n\u003ctd\u003e0010010802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.300 Check valve\u003c\/td\u003e\n\u003ctd\u003e0020011105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 10.400 Stand\u003c\/td\u003e\n\u003ctd\u003e0035001735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC 2.4 Pump control\u003c\/td\u003e\n\u003ctd\u003e0002439100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT 1000.60 Temperature sensor, stainless steel\u003c\/td\u003e\n\u003ctd\u003e0003516800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVH.SI.8 Vacuum hose\u003c\/td\u003e\n\u003ctd\u003e0020013886\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVSE 1\u003c\/td\u003e\n\u003ctd\u003e0035001873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC 1.3 Cable\u003c\/td\u003e\n\u003ctd\u003e0025005322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR-2.ST the High-Performer\u003c\/td\u003e\n\u003ctd\u003e0020013291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020112031.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991788949574,"sku":"0020112031","price":1627.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vc-10-pro-vacuum-controller.jpg?v=1794350762"},{"product_id":"ika-vacstar-lite-vacuum-pump","title":"IKA VACSTAR lite Vacuum pump","description":"\u003cp\u003eSpeed-controlled two-cylinder diaphragm vacuum pump for dry, oil-free vacuum work in the laboratory. Chemically resistant membranes and an ultimate vacuum of 9 mbar. Designed for use with rotary evaporators, laboratory reactors, tempering chambers and centrifuges.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e16.67 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure\u003c\/th\u003e\n\u003ctd\u003e9 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e115 x 292 x 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e8.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input standby\u003c\/th\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0020124926.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991845572678,"sku":"0020124926","price":1363.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-lite-vacuum-pump.jpg?v=1794352161"},{"product_id":"ika-vacstar-lite-advanced-plus-solution-vacuum-pump","title":"IKA VACSTAR lite Advanced Plus Solution Vacuum Pump","description":"\u003cp\u003eVacuum package for the laboratory: the VACSTAR lite vacuum pump with the VC 10 pro vacuum controller and the VSE 1 emission condenser, which keeps solvent vapours out of the room air. The controller detects the boiling point automatically using its built-in solvent library; manual setpoint entry and programmable pressure ramps are also available.\u003c\/p\u003e\n\u003cp\u003eScope of delivery\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVACSTAR lite\u003c\/li\u003e\n\u003cli\u003eVC 10 pro\u003c\/li\u003e\n\u003cli\u003eVSE 1\u003c\/li\u003e\n\u003cli\u003eVC 10.600 Stand pole\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e16.67 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure\u003c\/th\u003e\n\u003ctd\u003e9 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction levels\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e10 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTwo-point control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection for ext. temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003ePTFE, FFPM, PPS, NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum leakage test\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e260 x 502 x 377 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e11.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e144 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0010014499.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991847178310,"sku":"0010014499","price":3704.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-lite-advanced-plus-solution-vacuum-pump.jpg?v=1794352164"},{"product_id":"ika-vacstar-lite-advanced-solution-vacuum-pump","title":"IKA VACSTAR lite Advanced Solution Vacuum Pump","description":"\u003cp\u003eVacuum package for the laboratory: the VACSTAR lite vacuum pump with the VC 10 pro vacuum controller. The controller detects the boiling point automatically using its built-in solvent library; the setpoint can also be entered manually on the TFT display, and a program mode runs several pressure ramps.\u003c\/p\u003e\n\u003cp\u003eScope of delivery\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVACSTAR lite\u003c\/li\u003e\n\u003cli\u003eVC 10 pro\u003c\/li\u003e\n\u003cli\u003eVC 10.600 Stand pole\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e16.67 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure\u003c\/th\u003e\n\u003ctd\u003e9 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction levels\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e10 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiling point detection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSolvent library\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTwo-point control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection for ext. temperature sensor\u003c\/th\u003e\n\u003ctd\u003ePT1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003ePTFE, FFPM, PPS, NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum leakage test\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e115 x 445 x 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e144 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0010014498.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991847211078,"sku":"0010014498","price":3069.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-lite-advanced-solution-vacuum-pump.jpg?v=1794352167"},{"product_id":"ika-vacstar-lite-starter-plus-solution-vacuum-pump","title":"IKA VACSTAR lite Starter Plus Solution Vacuum Pump","description":"\u003cp\u003eVacuum package for the laboratory: the VACSTAR lite vacuum pump with the VC 10 lite vacuum controller and the VSE 1 emission condenser, which keeps solvent vapours out of the room air. The setpoint is entered manually on the TFT display, and a program mode runs several pressure ramps.\u003c\/p\u003e\n\u003cp\u003eScope of delivery\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVACSTAR lite\u003c\/li\u003e\n\u003cli\u003eVC 10 lite\u003c\/li\u003e\n\u003cli\u003eVSE 1\u003c\/li\u003e\n\u003cli\u003eVC 10.600 Stand pole\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e16.67 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure\u003c\/th\u003e\n\u003ctd\u003e9 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction levels\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e10 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmission condenser\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003ePTFE, FFPM, PPS, NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum leakage test\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e260 x 502 x 377 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e144 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0010014497.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991847505990,"sku":"0010014497","price":3158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-lite-starter-plus-solution-vacuum-pump.jpg?v=1794352171"},{"product_id":"ika-vacstar-lite-starter-solution-vacuum-pump","title":"IKA VACSTAR lite Starter Solution Vacuum Pump","description":"\u003cp\u003eVacuum package for the laboratory: the VACSTAR lite vacuum pump combined with the VC 10 lite vacuum controller. The setpoint is entered manually on the TFT display, and a program mode runs several pressure ramps. Suited to separation, filtration and drying, and to use with rotary evaporators, reactors, tempering chambers and centrifuges. A valve cleaning function removes solvent residues; USB and RS 232 interfaces connect to the labworldsoft® software.\u003c\/p\u003e\n\u003cp\u003eScope of delivery\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVACSTAR lite\u003c\/li\u003e\n\u003cli\u003eVC 10 lite\u003c\/li\u003e\n\u003cli\u003eVC 10.600 Stand pole\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e1 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump rate max. (50\/60Hz)\u003c\/th\u003e\n\u003ctd\u003e16.67 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinal pressure\u003c\/th\u003e\n\u003ctd\u003e9 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction levels\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput pressure\u003c\/th\u003e\n\u003ctd\u003e10 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed range\u003c\/th\u003e\n\u003ctd\u003e285 - 1100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eTFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl range\u003c\/th\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution pressure\u003c\/th\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting valve\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise at low. pressure\u003c\/th\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial in contact with medium\u003c\/th\u003e\n\u003ctd\u003ePTFE, FFPM, PPS, NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller control\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum leakage test\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e115 x 445 x 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e9.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class according to DIN EN 60529\u003c\/th\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS 232 interface\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input\u003c\/th\u003e\n\u003ctd\u003e144 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArticle no. 0010014496.\u003c\/strong\u003e Price on request – ask BIEL engineering for a quote.\u003c\/p\u003e","brand":"BIEL engineering","offers":[{"title":"Default Title","offer_id":50991847637062,"sku":"0010014496","price":2523.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/1477\/7414\/files\/ika-vacstar-lite-starter-solution-vacuum-pump.jpg?v=1794352174"}],"url":"https:\/\/bielengineering.com\/collections\/vacuum-pumps.oembed","provider":"BIEL engineering","version":"1.0","type":"link"}